Anion gap

Classification of metabolic acidosis

Sources last checked: 2026-10-13

Anion gap

Classification of metabolic acidosis

Fill in every field to see the result.

Potassium is not included here. The 12 mmol/L cut-off is conventional — reference ranges differ between laboratories and analysers.

Source: Figge J, Jabor A, Kazda A, Fencl V. Anion gap and hypoalbuminemia. Crit Care Med 1998;26(11):1807-1810.Open

Interpretation

Normal / low≤ 12 mmol/L — in metabolic acidosis, a gap in this range fits hyperchloraemic (normal-gap) acidosis.
High> 12 mmol/L — high-anion-gap acidosis (lactate, ketones, renal failure, toxins).

What is the Anion gap?

The anion gap is the difference between measured cations and anions in serum — sodium minus chloride and bicarbonate — and reflects unmeasured anions such as albumin, lactate and ketoacids. It is used to classify metabolic acidosis into high-gap and normal-gap (hyperchloraemic) forms. Because albumin is the main unmeasured anion, Figge and colleagues (1998) showed that each 1 g/dL fall in albumin lowers the gap by about 2.5 mmol/L and proposed a correction.

When to use it

  • Any metabolic acidosis (low bicarbonate, low pH), to separate high-gap from normal-gap causes.
  • Suspected toxic ingestion (methanol, ethylene glycol, salicylates), diabetic or alcoholic ketoacidosis, or lactic acidosis.
  • Critically ill or hypoalbuminaemic patients, in whom an uncorrected gap can hide a high-gap acidosis.

When not to use it

  • Without a matching blood gas or clinical context — an isolated gap value does not diagnose an acid-base disorder.
  • When sodium, chloride and bicarbonate come from different samples or analysers.

How it is calculated

AG = Na⁺ − (Cl⁻ + HCO₃⁻) Albumin-corrected AG = AG + 2.5 × (4.0 − albumin in g/dL) = AG + 0.25 × (40 − albumin in g/L)

Clinical pearls and limitations

  • Potassium is not included here. The 12 mmol/L cut-off is conventional — reference ranges differ between laboratories and analysers.
  • This calculator uses 4.0 g/dL (40 g/L) as normal albumin; Figge's correction uses the laboratory's own normal value, so results can differ by about 1 mmol/L.
  • European laboratories report albumin in g/L: divide by 10 for g/dL.
  • The upper limit of normal depends on the analyser — with modern ion-selective electrodes many laboratories quote roughly 3–11 mmol/L without potassium. Use local ranges.
  • In high-gap acidosis compare the rise in gap with the fall in bicarbonate (delta ratio) to detect a coexisting normal-gap acidosis or metabolic alkalosis.
  • A low or negative gap suggests laboratory error, hypoalbuminaemia, paraproteinaemia, or bromide or lithium intoxication.

Frequently asked questions

What is a normal anion gap?

Conventionally about 8–12 mmol/L without potassium, but modern analysers give lower values and ranges vary between laboratories. Interpret against your local reference range and the albumin level.

How do I correct the anion gap for albumin?

Add 2.5 mmol/L for every 1 g/dL (10 g/L) that albumin is below normal: corrected AG = AG + 2.5 × (4.0 − albumin in g/dL), or AG + 0.25 × (40 − albumin in g/L).

What causes a high anion gap metabolic acidosis?

Lactate, ketoacids (diabetic, alcoholic, starvation), advanced kidney failure, and toxins such as methanol, ethylene glycol and salicylates. Calculating the osmolar gap helps when toxic alcohols are suspected.

Evidence and guidelines

  1. Primary source: Figge J, Jabor A, Kazda A, Fencl V. Anion gap and hypoalbuminemia. Crit Care Med 1998;26(11):1807-1810.
  2. Kraut JA, Madias NE. Serum anion gap: its uses and limitations in clinical medicine. Clin J Am Soc Nephrol 2007;2(1):162-174 (normal range varies with analyser and laboratory).

Have a follow-up question?

Medelix answers clinical questions from current guidelines and studies — every statement with its source.

Ask Medelix about the Anion gap

Related calculators

Embed this calculatorFree to use on your website, intranet or teaching page. Copy the code below.
<iframe src="https://medelix.ai/en/embed/anion-gap" title="Anion gap – Medelix" width="100%" height="620" style="border:0;max-width:720px" loading="lazy"></iframe> <p><a href="https://medelix.ai/en/calculators/anion-gap">Anion gap calculator by Medelix</a></p>

For healthcare professionals and medical students. These tools support, and do not replace, clinical judgement. Always check results against the original source and your local protocols.